Hostname: page-component-cb9f654ff-5kfdg Total loading time: 0 Render date: 2025-08-24T08:21:33.021Z Has data issue: false hasContentIssue false

Powder X-ray diffraction of 5-Chloro-N-(4-nitrophenyl) pentanamide, C11H13ClN2O3

Published online by Cambridge University Press:  13 August 2015

Qing Wang
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
Yan Mei Huang
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
Qiao Mei Sun
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
Xiang Ling Ma
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
Hui Li*
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
*
a) Author to whom correspondence should be addressed. Electronic mail: lihuilab@sina.com
Rights & Permissions [Opens in a new window]

Abstract

X-ray powder diffraction data for 5-Chloro-N-(4-nitrophenyl)pentanamide, C11H13ClN2O3, are reported [a = 8.036(4) Å, b = 15.972(5) Å, c = 9.829(5) Å, α = 90°, β = 104.227(2)°, γ = 90°, V = 1222.98 Å3, Z = 4, ρ x = 1.3941 g cm−3 and space group P21/c]. All measured lines were indexed and are consistent with the P21/c space group. No detectable impurities were observed.

Information

Type
Rapid Communication
Copyright
Copyright © International Centre for Diffraction Data 2015 

5-Chloro-N-(4-nitrophenyl) pentanamide is an intermediate in the synthesis of the anticoagulant, Apixaban (Watson et al., Reference Watson, Whiteside and Perry2011; Jiang and Ji, Reference Jiang and Ji2013). Commercial 5-chloro-N-(4-nitrophenyl) pentanamide was purchased from Haoyuan Chemexpress Co., Ltd., (Shanghai, China), recrystallized in methanol and dried. The sample was then ground into powder (HPLC >98%, ρ = 1.391 g cm−3) and mounted on a flat zero background plate. X-ray powder diffraction measurement was performed at room temperature using an X'Pert PRO diffractometer (PANalytical Co., Ltd., The Netherlands) with a PIXcel 1D detector and Cu radiation (generator setting: 40 kV and 40 mA). The diffraction data were collected over the angular range from 4° to 50°2θ with a step size of 0.013 13°2θ and a counting time of 30 ms step−1. The software package Material Studio 8.0 (Accelrys Co., Ltd., CA, USA) was used to process the data in the Analytical & Testing Center (Sichuan University, China). The X-ray powder diffraction pattern was pre-treated by subtracting the background, smoothing, and stripping off the 2 component. Automatic indexing results were obtained by X-Cell method (Neumann, Reference Neumann2003). The preliminary cell from indexing was refined using the Pawley method (Pawley, Reference Pawley1981). The refinement confirmed that the sample crystallizes in the monoclinic space group P21/c (14), with a = 8.036(4) Å, b = 15.972(5) Å, c = 9.829(5) Å, α = 90°, β = 104.227(2)°, γ = 90°, V = 1222.98 Å3, Z = 4, and ρ x = 1.3941 g cm−3. Figure 1 shows the Powder X-ray diffraction pattern of the compound. The values of 2θ obs, d obs, I obs, h, k, l, 2θ cal, d cal, and 2θ are listed in Table SI.

Figure 1. Powder X-ray diffraction pattern of 5-Chloro-N-(4-nitrophenyl) pentanamide

ACKNOWLEDGEMENTS

This work was supported by the Applied Basic Research Project of Sichuan Province (Grant no. 2014JY0042), the Testing Platform Construction of Technology Achievement Transform of Sichuan Province (Grant no. 13CGPT0049), and the National Development and Reform Commission and Education of China (Grant no. 2014BW011).

SUPPLEMENTARY MATERIALS

For supplementary material for this article, please visit http://dx.doi.org/10.1017/S0885715615000664

References

Jiang, J. and Ji, Y. (2013). “Alternate synthesis of apixaban (BMS-562247), an inhibitor of blood coagulation factor Xa,” Synth. Commun. 43(1), 7279.CrossRefGoogle Scholar
Neumann, M. A. (2003). “X-Cell: a novel indexing algorithm for routine tasks and difficult cases,” J. Appl. Crystallogr. 36, 356365.CrossRefGoogle Scholar
Pawley, G. S. (1981). “Unit-cell refinement from powder diffraction scans,” J. Appl. Crystallogr. 14(6), 357361.CrossRefGoogle Scholar
Watson, J., Whiteside, G., and Perry, C. (2011). “Apixaban,” Drugs 71, 20792089.CrossRefGoogle ScholarPubMed
Figure 0

Figure 1. Powder X-ray diffraction pattern of 5-Chloro-N-(4-nitrophenyl) pentanamide

Supplementary material: File

Wang supplementary material

Wang supplementary material 1

Download Wang supplementary material(File)
File 113.9 KB
Supplementary material: File

Wang supplementary material

Table S1

Download Wang supplementary material(File)
File 155.6 KB